Off-Grid Solar System Configuration
Sunshine
Average Sunshine Hour(according to the local average sunshine time)Load
Rated Power W Load Working Time h Continuous Rainy Day Day Rainy Days Interval DayBattery
Single Voltage V Number Of Series Battery Voltage V Depth Of Discharge %Inverter
Conversion Rate % Load Working Power (max)/Inverter Rated Power %MPPT Controller
Conversion Rate % Solar Array Power/MPPT Controller Rated Power %Solutions
Load Required Power Generation(Per Day) 29.24 WhDisclaimyouers:
1. The above data is for reference only。
2. When the calculated result is invalid, please re-enter the correct parameters。
3. You can contact HearGrow for engineer services
This system is supported by https://www.heargrow.com/
On-Grid Connection
Site Environment
Floor Area M2 Solar Panel Area Ratio %Sunshine
Average Sunshine Hour(according to the local average sunshine time)Sell electricity
Unit price(kilowatt) $Solar Panels
Power Generation Efficiency % Estimated Allocation Ratio %Grid Inverter
MPPT Input Voltage VDC Output Voltage VAC Stand-alone Power W Conversion Efficiency %Solutions
Total generating power 75000W Total generating power 0.0750MWDisclaimers:
1. The above data is for reference only。
2. When the calculated result is invalid, please re-enter the correct parameters。
3. You can contact HearGrow for engineer services。
This system is supported by https://www.heargrow.com/
Solar Panel Series And Parallel Recommendation
Solar Array
Rated Power W Estimated Allocation Ratio % Total Power WSingle Panel
Rated Power W Single Voc V Single Vmpp VBattery Pack
Single Voltage V Number Of Series PCS Battery Pack Voltage VMPPT Controller
Max. Input Voc VSolutions
Number Of Solar Panels PSCDisclaimers:
1. The above data is for reference only。
2. When the calculated result is invalid, please re-enter the correct parameters。
3. You can contact HearGrow for engineer services。
This system is supported by https://www.heargrow.com/
Battery Series-Parallel Configuration
Electricity Demand
Capacity WhSingle battery/cell
Single Voltage V Single Capacity Ah Number Of Series Depth Of Discharge %Solutions
Single Parallel Quantity 5.2PCS Battery Pack Capacity 520.8AhDisclaimers:
1. The above data is for reference only。
2. When the calculated result is invalid, please re-enter the correct parameters。
3. You can contact HearGrow for engineer services。
This system is supported by https://www.heargrow.com/
Solar module design (cell arrangement)
Component requirements
Power WRated voltage V Open circuit voltage V
Width(Wide) mm
Battery cell parameters
Rated voltage V Open circuit voltage VRated power W
Size lengthmm * Size widthmm Commonly Used Size
Horizontal spacing mm Longitudinal spacing mm
Border width mm
Solutions
Battery usage 60PCSNumber of series connections 60PCS Parallel quantity 1PCS
Total power 456.00W
Rated voltage 30.00V Open circuit voltage 36.00V
Rated current 15.20A Short-circuit current 18.24A
Number of long edges 10PCS * Wide edge quantity 6PCS
Minimum size of long side 1810.33mm Minimum size of long side 1175.00mm